National annexes
Czech Republic
Following rules are used for the determination of the snow load according to CSN EN 1991-1-3/NA:
- The map and list of snow regions is used according to the amendment Z1 CSN EN 1991-1-3:2005.
- The load figure according to the figure NA.1 is used for cylindrical roofs with h/b> 1/8 or with snowguards and in snow regions IV and V.
Following rules are used for the determination of the wind load according to CSN EN 1991-1-4/NA:
- The map and list of wind regions is used according to the CSN EN 1991-1-4:2007.
Slovakia
Following rules are used for the determination of the snow load according to STN EN 1991-1-3/NA:
- Tha values of sk are calculated according to the chapter NA.2.8 of STN EN 1991-1-3/NA1:2012.
- The map and list of snow regions is used according to the Annex C of STN EN 1991-1-3/NA1:2012.
- The map and list of regions with accidental load is used according to the Annex C of STN EN 1991-1-3/NA1:2012.
Following rules are used for the determination of the wind load according to STN EN 1991-1-4/NA:
- The map and list of wind regions is used according to the STN EN 1991-1-4:2008.
- Pressure coefficients cpe for flat roofs are selected according to the table 7.2/NA.
- Pressure coefficients cpe for mono-pitched roofs are selected according to the table 7.3/NA.
- Pressure coefficients cpe for duo-pitched roofs are selected according to the table 7.4/NA.
- Pressure coefficients cpe for hip roofs are selected according to the table 7.5/NA.
Poland
Following rules are used for the determination of the snow load according to PN EN 1991-1-3/NA:
- The map and list of snow regions is used according to the NB1.7 of PN EN 1991-1-3:2005.
Following rules are used for the determination of the wind load according to PN EN 1991-1-4/NA:
- The map and list of wind regions is used according to the PN EN 1991-1-4:2008.
Austria
Following rules are used for the determination of the snow load according to ÖNORM B 1991-1-3:
- The map and list of snow regions is used according to the 8.1.2 of ÖNORM B 1991-1-3:2022. The map is accessible from hora.gv.at.
- Coefficient for exceptional snow loads Cesl is used according to chapter 8.3.
- Exposure coefficient Ce is used according to chapter 9.1.4.
- Thermal coefficient Ct is used according to chapter 9.1.5.
- Snow load shape coefficients μ1, μ2 are used according to chapter 9.2.1.2 Table 2.