0
Programmi:
Lingua:

Facing Reduction Coefficient μ

The coefficient μ accounts for the interaction between the slope facing and the nail heads when determining the total bearing capacity of nail. Its value ranges from 0 to 1 and depends on the facing type, structural arrangement and contact conditions with the ground.

  • μ = 0: the contribution of the facing is neglected.
  • 0 < μ < 1: the contribution of the facing is partially taken into account.
  • μ = 1: the nail head resistance is considered without reduction by μ

A higher value of μ allows a greater contribution of the facing to load transfer.

Indicative Values of the Coefficient μ

μ

Typ krytu

0,0

Vegetation cover, erosion control mats

0,2–0,6

Shotcrete facing

0,4–0,7

Wire-rope-connected facing systems

0,7–1,0

Wire-rope-connected facing systems

0,7–1,0

Individual bearing plates

0,7–1,0

Concrete grid frame facing

1,0

Continuous rigid concrete facing

Note: The selection of μ must also account for nail spacing and length, ground properties and the design guidance for the selected system. The coefficient μ does not replace verification of the facing and nail head resistance.

Sources:

NEXCO: Guidelines for the Design and Construction of Soil Nailing, January 2007, p. 50 (basic categories).

Daisho Co., Ltd.: Recommended Facing Reduction Factor (μ), technical document for GEO5 (additional values for wire-rope systems, high-tensile wire mesh and individual bearing plates).

Prova il Software GEO5.
Gratuitamente.